RipEX2-HS |
Standard units |
Yes |
|
Hot swappable |
Yes, easier |
|
Interfaces |
1×ETH, 1×SFP, 1×COM |
|
Internal fan |
No |
|
Mounting |
More options |
|
Two power supplies |
Yes |
|
Battery pack |
No |
|
Internal duplexer |
Optional |
|
No controller |
Optional |
|
Radio parameters |
RipEX-HS |
RipEX2-HS |
|
The same as RipEX units used |
The same as RipEX2 units used |
Hot Standby |
Switch-over time |
< 2 s |
|
Electrical |
Primary power |
HW models |
HW models |
100 – 240 VAC, 50 – 60 Hz 36 – 60 VDC, positive grounding possible |
11 – 30 VDC |
10 – 30 VDC 18 – 30 VDC, positive grounding possible |
Individual power supply for each unit |
RipEX-HSB |
RipEX-HSB For AC power model Output 2 x 24 V / 7.2 Ah |
No |
|
Interfaces |
|
detail |
detail |
Ethernet |
3× 10/100Base-T Auto MDI/MDIX, RJ45 |
1× 10/100/1000 Base-T Auto MDI/MDIX, RJ45 |
SFP |
No |
1× 10/100/1000Base-T/1000Base-SX/1000Base-LX |
COM 1 |
RS232, DB9F 300 – 115 200 bps |
RS232/RS485 SW configurable, DB9F 300 bps – 1 Mbps |
COM 2 |
RS232/RS485 SW configurable, DB9F, 300–115 200 bps |
No |
USB |
USB 1.1 / Host A, for each RipEX unit |
USB 3.0 / Host A, for each RipEX2 unit |
Antenna |
N-female(s) / 50 Ohms |
HW models |
HW models |
|
Environmental |
IP Code (Ingress Protection) |
IP20 |
IP30 |
MTBF (Mean Time Between Failure) |
> 500.000 hours (> 50 years) |
> 900 000 (> 100 years) |
Operating temperature |
–10 to +60 °C (14 to 140 °F) – standard –40 to +70 °C (-40 to + 158 °F) – optionally |
–40 to +70 °C (-40 to +158 °F) |
Humidity |
5 to 95% non-condensing |
Storage |
−40 to +85 °C (−40 to +185 °F) / 5 to 95 % non-condensing |
Internal fans |
Automatically start-up when temperature exceeds 50 °C |
No |
|
Mechanical |
Dimensions |
19″ rack 3U 482 W × 401 D × 133 H mm (18,98 × 15.79 × 5,24 in) |
19″ rack 3U 442 W × 392D × 120H mm (17.40 × 15.43 × 4.72 in) |
Weight |
7.1 kg (15.7 lbs), RipEX unit exl. 9.1 kg (20.1 lbs), RipEX unit incl. |
8.9 kg (19.6 lbs), RipEX2 unit exl. 12.1 kg (26.7 lbs), RipEX2 unit incl. |
|
Diagnostics and Management |
|
Same tools as with standard RipEX units used |
LED panels |
Standard RipEX LED panel: Power, ETH, COM1, COM2, Rx, Tx, Status HS controller – for each unit: Active, Power supply, Battery, Alarm |
Standard RipEX2 LED panel: SYS, AUX, RX, TX, COM HS controller: A, AUTO, B, SFP |
HW Alarm outputs |
RipEX A, RipEX B, Switch, Power |
RipEX2 A, RipEX2 B, Controller, General alarm |
|
|
|
|
|
|