Designation |
100Base-FX |
Typical Distance |
2 km |
Nominal Wavelength |
1310 nm |
Cable Type |
62.5 / 125 MM |
Connector |
SC |
Optical Budget |
15 dB |
Serial Interface |
92000 |
8-port 10/100Base-TX |
Forward and Filtering Rate |
92000 |
148,810 pps for 100 Mbps, 14,880 pps for 10 Mbps |
Address Table Size |
92000 |
2048 MAC addresses |
Latency |
92000 |
Less than 7.1 μs |
Reverse Polarity Protection |
92000 |
n/a |
Network Interface |
92000 |
10/100 Mbps full/half-duplex, auto negotiation, auto MDI/MDIX |
LED Indicators |
92000 |
Per Unit: Power Status (Power 1, Power 2)Per Port: 10/100TX, 100FX:Link/Activity (Green), Speed (Yellow), Fault (Red) |
Management |
92000 |
n/a |
Alarm Contact |
92000 |
One relay output with current 1A @ 24 VDC |
Standards |
92000 |
IEEE802.3 10Base-T, IEEE802.3u 100 Base-TX/100Base-FX, IEEE802.3x |
Power |
92000 |
Input Voltage: 10 to 48 VDCInput Current: 1.5A max.Power Consumption: 24 VDC @ 0.55A, 18.48 W max. |
Environmental |
92000 |
Operating Temperature: -34° to 74° ° C (-29° to 165° F)Storage Temperature:-40° to 85° C (-40° to 185° F)Humidity: 10% to 95% relative humidity (non-condensing) |
Protocols Supported |
92000 |
n/a |
Packet Buffer Memory |
92000 |
768 Kb |
Packaging |
92000 |
Aluminum case with DIN-rail, or panel mounting |
Dimensions |
92000 |
50 mm W x 110 mm D x 136 mm H(1.97″ W x 4.33″ D x 5.35″ H) |
Weight |
92000 |
0.8 Kg (1.76 lb) |
Processing Types |
92000 |
Store-and-forwardHalf-duplex back-pressure and IEEE802.3x full-duplex flow control |
Standards |
92000 |
IEEE802.3 10Base-T, IEEE802.3u 100 Base-TX/100Base-FX, IEEE802.3x |
Regulatory Approvals |
Emission Compliance |
FCC Part 15, Class A |
ISO |
92000: Manufactured in an ISO9001 facility |
Safety |
52000: UL 6095092000: UL 60950, EN 60950, IEC 60950, IEC 61000-6-2, UL 1604: Classified for ITE Equipment for use in hazardous locations: Class 1, Division 2 group A, B, C & D:Temp Code T4A; -25C° < Tamb < 74C° |
CE Approval |
52000: n/a92000: EN55022 (CISPR22 Class A), EN55024 (CISPR24 Class A) |
ESD Standards (IEC 61000-4-2) |
92000 |
Enclosure Contact: + / – 4 kV; Criteria B, Enclosure Air: + / – 8 kV; Criteria B |
Radiated FRI Standards (IEC 61000-4-3) |
92000 |
Enclosure Ports: 10 V/m, 80 to 1000 MHz; Criteria A |
Burst Standards (IEC 61000-4-4) |
92000 |
Enclosure Ports: + / – 4 kV @ 2.5 KHz; Criteria B, DC Power Ports: + / – 4 kV; Criteria B, AC Power Ports: + / – 4 kV; Criteria B |
Surge Standards (IEC 61000-4-5) |
92000 |
Signal Ports: + / – 1 kV; Line-to-earth; Criteria B, DC Power Ports: + / – 0.5 kV; Line-to-earth; Criteria B AC Power Ports: + / – 2 kV; Line-to-earth; Criteria B |
Induced RFI Standards (IEC 61000-4-6) |
92000 |
Signal Ports: 10V @ 0.15 – 80 MHz; Criteria A, DC Power Ports: 10V @ 0.15 – 80 MHz; Criteria AAC Power Ports: 10V @ 0.15 – 80 MHz; Criteria A, Earth Ground Ports: 10V @ 0.15 – 80 MHz; Criteria A |
Magnetic Field Standards (IEC 61000-4-8) |
92000 |
Enclosure Ports: 30 A/m @ 50, 60 Hz; Criteria A |
Voltage Dip Standards (IEC 61000-4-11) |
92000 |
AC Power Ports: 30% Reduction for 0.5 period; Criteria B |
Environmental Test Compliance |
92000 |
(IEC 60068-2-6) Vibration Resistance: 5G @ 150 Hz; Criterion 3 (Operation/Storage/Transport)(IEC 60068-2-27) Shock:• 5 G @ 11 ms (Half-Sine Shock Pulse; Operation)• 50 G @ 11 ms (Half-Sine Shock Pulse; Storage/Transport)(IEC 60068-2-32) Free Fall: 1 M (3.281 ft.) |
NEMA TS1/2 Environmental Requirements for Traffic Control Equipment |
92000 |
Yes |
Installation Type |
92000 |
DIN Rail (mounting kit is included)Optional wall-mount kit, ordered separately (X9294PMKT-01) |