Software functions |
|
Switching |
Supports VLAN, PVLAN Supports GVRP Supports port aggregation, LACP Supports port flow control Supports Rate limit based on flow (ACL Rate Limiter) Supports Global broadcast storm suppression (QOS Storm Policing) |
|
Redundancy |
Supports DT-Ring, DT-Ring+, DT-VLAN with the recovery time<50ms Supports DRP/DHP with the recovery time<20ms Supports STP/RSTP/MSTP |
|
Multicast |
Supports IGMP snooping Supports GMRP Supports static multicast |
|
Network Security |
Supports HTTPS/SSL Supports SSH Supports TACACS+ Supports IEEE802.1X Supports RADIUS Supports User Classification Supports MAC address binding with switch ports |
|
Service Quality |
Supports QoS, 802.1p(CoS), DSCP Supports SP, WRR queue scheduling Supports ACL |
|
Industrial protocol |
Supports PROFINET (PROFINET Conformance Class B, PROFINET IO diagnosis, GSD files, Configuration and diagnostic via STEP 7) Supports EtherNet/IP Supports Modbus/TCP |
|
Management and Maintenance |
Supports Console, Telnet, WEB management methods Supports SNMPv1/v2c/v3, Kyvision centralized management Supports software upgrade by SFTP/HTTP Supports Power alarm, IP/MAC conflict alarm, Memory/CPU usage alarm, Port alarm, Ring alarm, Port traffic alarm, CRC error and packet lose alarm, SFP port RX power alarm and TX power alarm Supports DDM (SFP port) Supports loop detection Supports RMON Supports port mirroring Supports Syslog Supports LLDP Supports Link-check Supports Automatic Configuration Backup and Restore |
|
IP Management |
Supports DHCP server/snooping/client, DHCP Option 82 Supports ARP |
|
Clock Management |
Supports SNTP Client Supports PTP |
|
Technical Specification |
|
|
|
Technical Parameter |
Standard IEEE 802.3i (10Base-T) IEEE 802.3u (100Base-T and 100Base-FX) IEEE 802.3ab (1000Base-T) IEEE 802.3z (1000Base-SX/LX) IEEE 802.3ad (Link aggregation) IEEE 802.3x (Flow Control) IEEE 802.1p (Class of Service) IEEE 802.1Q (VLAN) IEEE 802.1d (STP) IEEE 802.1w (RSTP) IEEE 802.1s (MSTP) IEEE 802.1x (Network Access Control) IEEE 802.1ab (LLDP) IEEE1588 V2 (PTP) |
|
Switch Properties |
Priority Queues 8 Number of VLANs 4K VLAN ID 1~4094 Number of Multicast Groups 8K MAC Table 8K Packet Buffer 4Mbit Packet Forwarding Rate 1.5Mpps (2SFP8T), 1.8Mpps (4SFP8T) 4.2Mpps (2GX8T), 7.2Mpps (4GX8T) 14.9Mpps (2GX8GE), 17.9Mpps (4GX8GE) 3.0Mpps (4SFP16T), 8.3Mpps (4GX16T) 2.4Mpps (8SFP8T), 13.1Mpps (8GX8T) 29.8Mpps (4GX16GE,12GX8GE), 23.8Mpps (8GX8GE) Switching Delay <5μs Jumbo frame 9.6KB |
|
Interface |
Gigabit Port 100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP slot 10/100/1000Base-T(X), RJ45 port, Auto MDI/MDI-X connection Fast Ethernet Port 100Base-X SFP slot 10/100Base-T(X), RJ45 port, Auto MDI/MDI-X connection Console Port RJ45, RS232 Alarm Contact 3-pin 5.08mm-spacing plug-in terminal block, 250VAC/220VDC Max, 2A Max |
|
LED |
LEDs on Front Panel Running LED: Run Alarm LED: Alarm Power LED: PWR1,PWR2 Ring LED: Ring Interface LED: Link/ACT, Speed (RJ45 port); Link/ACT(Fiber port) |
|
Button |
Reset: Reboot and restore default configuration |
|
Power Requirement |
Power Input 100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC) 24-48VDC(18-72VDC) 12-24VDC(9-36VDC) Power Terminal 5-pin 5.08 mm-spacing plug-in terminal block (L2/L5) 3-pin 7.62 mm-spacing plug-in terminal block (HV) Power Consumption Overload Protection Support Reverse Protection Support Redundancy Protection Support (12/24/48VDC) |
|
Physical Characteristics |
Housing Metal Cooling Natural convection, fanless Protection Class IP40 Dimension 66mm×135mm×107.5mm (6T,8T,2GX8T,4GX8T) (W×H×D) 88mm×135mm×137mm (8GE,2GX8GE,4GX8GE) (W×H×D) 102mm×135mm×137mm (16GE,2GX16GE,4GX16GE,8GX8GE,12GX8GE) (W×H×D) Weight 1.1Kg (6T,8T,2GX8T,4GX8T) 1.5Kg (8GE,2GX8GE,4GX8GE) 1.9Kg (16GE,2GX16GE,4GX16GE,8GX8GE,12GX8GE) Mounting DIN-Rail or Panel Mounting |
|
Environmental Limit |
Operating Temperature -40℃~+75℃ Storage Temperature -40℃~+85℃ Ambient Relative Humidity 5~95% (non-condensing) |
|
Warranty |
MTBF 1681195h (6T) 1675852h (8T) 1657563h (4GX8T) 1317486h (4GX8GE) 1272643h (12GX8GE) 1097144h (4GX16GE) Warranty 5 years |
|
Approvals |
CE, FCC EMC: EN 55032/35, EN 61000-6-4, EN 61000-6-2 Rail Traffic: EN 50121-4 UL61010 IEC61850-3, IEEE1613 PROFINET Conformance Class B |
|
Industrial Standard |
EMI: FCC CFR47 Part 15,EN55032/CISPR22,Class A EMS: IEC61000-4-2(ESD) ±6kV(contact),±8kV(air) IEC61000-4-3(RS) 10V/m(80MHz~2GHz) IEC61000-4-4(EFT) Power Port:±2kV;Data Port:±1kV IEC61000-4-5(Surge) Power Port:±1kV/DM,±2kV/CM;Data Port:±1kV IEC61000-4-6(CS) 10V(150kHz~80MHz) Machinery: IEC60068-2-6 (vibration) IEC60068-2-27 (shock) IEC60068-2-32 (free fall) Climatic environmental: IEC60068-2-1 Cold test IEC60068-2-2 Dry heat test IEC60068-2-14 Change of temperature test IEC60068-2-30 Damp heat cyclic test IEC60068-2-78 Damp heat steady state test |
|