Standards |
IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1p for Class of Service IEEE 802.1Q for VLAN Tagging IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.1X for authentication IEEE 802.3 for 10BaseT IEEE 802.3ab for 1000BaseT(X) IEEE 802.3ad for Port Trunk with LACP IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3x for flow control IEEE 802.3z for 1000BaseSX/LX/LHX/ZX |
Cabling Direction |
PT-7710-F Series: Front cabling PT-7710-D Series: Down cabling |
Compatible Modules |
Slot 1: PM-7200-8TX, PM-7200-2MSC4TX, PM-7200-2MST4TX, PM-7200-2SSC4TX, PM-7200-4MSC2TX, PM-7200-4MST2TX, PM-7200-4SSC2TX, PM-7200-6MSC, PM-7200-6MST, PM-7200-6SSC, PM-7200-8SFP, PM-7200-4M12, PM-7200-8MTRJ Slot 2: PM-7200-2GTXSFP, PM-7200-1MSC, PM-7200-1MST, PM-7200-2MSC, PM-7200-2MST, PM-7200-2SSC |
Filter
|
802.1Q, GMRP, GVRP, IGMP v1/v2c, Port-based VLAN, VLAN unaware |
|
• |
Management |
Back Pressure Flow Control, BOOTP, DHCP Option 66/67/82, DHCP Server/Client, Flow control, HTTP, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTP |
Security |
Broadcast storm protection, HTTPS/SSL, TACACS+, Port Lock, RADIUS, Rate Limit, SSH
|
Time Management
Filter
|
NTP Server/Client, SNTP
802.1Q, GMRP, GVRP, IGMP v1/v2/v3
|
MIB |
Bridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RMON MIB Groups 1, 2, 3, 9, RSTP MIB
|
Industrial Protocols |
Modbus TCP, EtherNet/IP |
Redundancy Protocols |
Link Aggregation, MSTP, RSTP, STP, Turbo Chain, Turbo Ring v1/v2
|
|
IGMP Groups
Max. No. of VLANs
VLAN ID Range
Priority Queues
|
256
64
VID 1 to 4094
4
|
Input Voltage |
PT-7710-LV Series: 12/24/48 VDC (9 to 60 VDC) PT-7710-HV Series: 110/220 VAC/VDC (88 to 300 VAC, 85 to 264 VDC) |
Overload Current Protection |
Supported
|
Reverse Polarity Protection |
Supported |
Input Current |
PT-7710-LV Series: 0.75 A @ 0.24 VDC, 0.39 A @ 48 VDC
PT-7710-HV Series: 0.19/0.11 A @ 110/220 VAC, 0.16/0.10 A @ 110/220 VDC
|
|
|
Console Port |
RS-232 (RJ45) |
• Power Requirements |
|
|
Connection |
10-pin terminal block |
Overload Current Protection |
Supported |
Time |
316,716 hrs
|
Reverse Polarity Protection |
Supported |
• Physical Characteristics |
Housing |
Aluminum
|
Dimensions |
266.5 x 44 x 195 mm (10.5 x 1.7 x 7.7 in) |
Weight |
2200 g (4.89 lb)
|
Installation |
PT-7710-F Series: 19-inch rack mounting, PT-7710-D Series: Wall mounting |
|
Operating Temperature |
-40 to 85°C (-40 to 185°F)
|
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
|
Safety |
EN 60950-1, UL 60950-1, CSA C22.2 No. 60950-1
|
EMI |
EN 55032 Class A, CISPR 32, FCC Part 15B Class A
|
EMS |
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 35 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV PT-7710-HV Series: IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV PT-7710-LV Series: IEC 61000-4-5 Surge: Power: 2 kV; Signal: 4 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF IEC 61000-4-11 DIPs |
Power Substation |
IEC 61850-3, IEEE 1613
|
Railway |
EN 50121-4, EN 50155 (complies with a portion of EN 50155 specifications)
|
Traffic Control |
NEMA TS2
|
Alarm Contact Channels |
Resistive load: 3 A @ 30 VDC, 240 VAC |
|
|