IOLAN SDS4 HL |
Processor |
MPC852T, 66 Mhz, 87 MIPS |
Memory |
RAM MB |
32 |
Flash MB |
8 |
Interface Ports |
Number of Serial Ports |
4 |
Serial Port Interface |
Software selectable EIA-232/422/485 on RJ45 |
Sun / Solaris |
Sun / Oracle ‘Solaris' Safe - no "break signal" sent during power cycle causing costly server re-boots or downtime |
Serial Port Speeds |
50bps to 230Kbps with customizable baud rate support |
Data Bits |
5,6,7,8, 9-bit protocol support |
Parity |
Odd, Even, Mark, Space, None |
Flow Control |
Hardware, Software, Both, None |
Serial Port Protection |
15Kv Electrostatic Discharge Protection ( ESD ) |
Local Console Port |
RS232 on Serial Port |
Network |
10-base T / 100-base TX Ethernet RJ45 |
Software selectable Ethernet speed 10/100 Auto |
Software selectable Half/Full/Auto duplex |
Ethernet Isolation |
1.5Kv Magnetic Isolation |
Power |
Power Supply Options |
Power via External power 9-30v DC, 4.8 Watts Terminal Block connector Power IN over serial cable |
Nominal Inut Voltage |
12v DC |
Input Voltage Range |
9-30v DC |
Input IOLAN over Serial |
9-30v DC |
Typical Power Consumption @ 12v DC ( Watts ) |
2.4 |
Indicators |
LEDs |
Power/Ready |
Network Link |
Network Link activity |
Serial: Transmit and Receive data per port |
Environmental Specifications |
Heat Output ( BTU/HR ) |
8.2 |
MTBF ( Hours )* |
118,466 |
Operating Temperature |
-40C to 74C, -40F to 165F |
Storage Temperature |
-40C to 85C, -40F to 185F |
Humidity |
5 to 95% (non condensing) for both storage and operation. |
Case |
SECC Zinc plated sheet metal (1 mm) |
Ingress Protection Rating |
IP40 |
Mounting |
Wall or Panel mounting, DIN Rail mounting kit optional |
Product Weight and Dimensions |
Weight |
0.7 Kg (1.6 lbs) |
Dimensions |
11.3 x 8.1 x 2.8 (cm), 4.4 x 3.2 x 1.1 (in) |
Packaging |
Shipping Dimensions |
25.5 x 16.5 x 6.5 (cm), 10 x 6.5 x 2.6 (in) |
Shipping Weight |
1.1 Kg (2.4 lbs) |
Regulatory Approvals |
Emissions |
FCC Part 15, Subpart B, Class A |
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A |
ICES-003, Issue 4, February 2004 (Canada) |
CISPR 32:2015/EN 55032:2015 (Class A) |
EN55011 (CISPR11) |
EN61000-3-2 : 2010, Limits for Harmonic Current Emissions |
EN61000-3-3 : 2010, Limits of Voltage Fluctuations and Flicker |
Immunity |
CISPR 24:2010/EN 55024:2010 |
EN61000-4-2: Electrostatic Discharge |
EN61000-4-3: RF Electromagnetic Field Modulated |
EN61000-4-4: Fast Transients |
EN61000-4-5: Surge |
EN61000-4-6: RF Continuous Conducted |
EN61000-4-8: Power-Frequency Magnetic Field |
EN61000-4-11: Voltage Dips and Voltage Interruptions |
Safety |
IEC 60950-1(ed 2); am1, am2 and EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 |
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1, First Edition April 1st 2003 (Recognized Component) |
Hazardous Locations |
EN 60079-0:2012+A11:2013, EN 60079-15:2010 and EN 60079-11:2012 ANSI/ISA - 12.12.01 - 2012 Class I and II, Division 2 and Class III, Division 1 and 2 ( classified ) locations ( UL-1604 ) CSA C22.2 No. 213 - M1987, R2008 ATEX Class 1 Zone 2 |