IOLAN SDG |
IOLAN SDS |
Processor |
600 Mhz ARM processor |
MPC852T, 66 Mhz, 87 MIPS |
Memory |
RAM MB |
512 |
32 |
Flash MB |
4000 |
8 |
Interface Ports |
Number of Serial Ports |
1, 2, 4 or 8 |
1, 2 or 4 |
Serial Port Interface |
Software selectable EIA232/422/485 on |
1 Port: DB9M, RJ45 or DB25F 2 Port: RJ45 4 Port: RJ45 8 Port: RJ45 |
1 Port: DB9M, RJ45, DB25M or DB25F 2 Port: RJ45 4 Port: RJ45 |
Sun / Solaris |
Sun / Oracle ‘Solaris' Safe - no "break signal" sent during power cycle causing costly server re-boots or downtime |
Serial Port Speeds |
300bps to 230Kbps with customizable baud rate support |
50bps to 230Kbps with customizable baud rate support |
Data Bits |
5,6,7,8, 9-bit protocol support |
Parity |
Odd, Even, Mark, Space, None |
Flow Control |
Hardware, Software, Both, None |
Serial Port Protection |
15Kv Electrostatic Discharge Protection ( ESD ) |
Local Console Port |
RS232 on Serial Port |
Network |
Autosensing 1000Base-T / 100Base-TX / 10Base-T Auto-MDIX |
10Base-T / 100Base-TX Ethernet RJ45 |
Software selectable Ethernet speed 10/100/1000 Auto |
Software selectable Ethernet speed 10/100 Auto |
Software selectable Half/Full/Auto duplex |
Ethernet Isolation |
1.5Kv Magnetic Isolation |
|
IOLAN SDG |
IOLAN SDS |
Power |
Power Supply |
120 V AC (USA), 230V AC (International) Wall Power Adaptor included |
Power Supply Options |
Power via External power 9-30v DC, 4.8 Watts uses standard 5.5mm x 9.5mm x 2.1mm barrel socket, Power IN over serial cable |
Nominal Input Voltage |
12v DC / 24v DC |
Input Voltage Range |
9-30v DC |
Power IOLAN over Serial |
9-30v DC |
Power External Device via Serial Port |
+5v DC regulated, 1W max |
Typical Power Consumption '@ 12v DC ( Watts ) |
1 Port: 1.9 2 Port: 2.0 4 Port: 2.0 8 Port: 2.7 |
1 Port: 1.7 2 Port: 2.1 4 Port: 2.4 |
Does not include power for devices connected to serial port |
Indicators |
LEDs |
Power/Ready |
Network Link |
Network Link activity |
Serial: Transmit and Receive data per port |
|
IOLAN SDG |
IOLAN SDS |
Environmental Specifications |
Heat Output ( BTU/HR ) |
1 Port: 6.80 2 Port: 8.90 4 Port: 16.38 8 Port: 9.20 |
1 Port: 5.8 2 Port: 7.2 4 Port: 8.2 |
MTBF ( Hours )
Calculation model based on MIL-HDBK-217-FN2 @ 30 °C
|
1 Port: 238,681 2 Port: 218,646 4 Port: 187,919 8 Port: 126,364 |
1 Port: 123,192 2 Port: 188,596 4 Port: 150,124 |
Operating Temperature |
0C to 55C, 32F to 131F |
Storage Temperature |
-40C to 66C, -40F to 150F |
Humidity |
5 to 95% (non condensing) for both storage and operation. |
Case |
SECC Zinc plated sheet metal (1 mm) |
Ingress Protection Rating |
IP40 |
Mounting |
Wall or Panel mounting, DIN Rail mounting kit optional |
|
IOLAN SDG |
IOLAN SDS |
Product Weight and Dimensions |
Weight |
1 Port: 0.23 kg (0.50 lbs) 2 Port: 0.23 kg (0.50 lbs) 4 Port: 0.35 kg (0.77 lbs) 8 Port: 0.55 kg (1.20 lbs) |
1 Port: 0.23 kg (0.50 lbs) 2 Port: 0.23 kg (0.50 lbs) 4 Port: 0.35 kg (0.77 lbs) |
Dimensions
(without mounting tabs)
|
1 Port: 90 x 64 x 22 (mm) 3.6 x 2.5 x 0.87 (in) 2 Port: 90 x 64 x 22 (mm) 3.6 x 2.5 x 0.87 (in) 4 Port: 112 x 82 x 28 (mm) 4.4 x 3.2 x 1.1 (in) 8 Port: 112 x 156 x 28 (mm) 4.4 x 6.1 x 1.1 (in) |
1 Port: 90 x 64 x 22 (mm) 3.6 x 2.5 x 0.87 (in) 2 Port: 90 x 64 x 22 (mm) 3.6 x 2.5 x 0.87 (in) 4 Port: 112 x 82 x 28 (mm) 4.4 x 3.2 x 1.1 (in) |
Dimensions
with mounting tabs
|
1 Port: 90 x 89 x 24 (mm) 3.6 x 3.5 x 0.87 (in) 2 Port: 90 x 89 x 24 (mm) 3.6 x 3.5 x 0.87 (in) 4 Port: 112 x 105 x 28 (mm) 4.4 x 4.2 x 1.1 (in) 8 Port: 113 x 179 x 28 (mm) 4.4 x 7.1 x 1.1 (in) |
1 Port: 90 x 89 x 24 (mm) 3.6 x 3.5 x 0.87 (in) 2 Port: 90 x 89 x 24 (mm) 3.6 x 3.5 x 0.87 (in) 4 Port: 112 x 105 x 28 (mm) 4.4 x 4.2 x 1.1 (in) |
Packaging |
Shipping Dimensions |
260 x 170 x 70 (mm), 10.2 x 6.7 x 2.8 (in) |
Shipping weight |
1 Port: 0.49 kg (1.1 lbs) 2 Port: 0.49 kg (1.1 lbs) 4 Port: 0.66 kg (1.5 lbs) 8 Port: 1.30 kg (2.9 lbs) |
1 Port: 0.49 kg (1.1 lbs) 2 Port: 0.49 kg (1.1 lbs) 4 Port: 0.66 kg (1.5 lbs) |
Regulatory Approvals |
Emissions |
CFR47 FCC Part 15 Subpart B:2015 |
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A |
ICES-003:2016 Issue 6:2016 |
ICES-003, Issue 4, February 2004 (Canada) |
CISPR 32:2015/EN 55032:2015 (Class A) |
EN55011 (CISPR11) |
CISPR 16-2-3:2010/A2:2014 |
|
EN61000-3-2:2014, Limited for Harmonic Current Emissions |
EN61000-3-2 : 2010, Limits for Harmonic Current Emissions |
EN61000-3-3:2013, Limits of Voltage Fluctuations and Flicker |
EN61000-3-3 : 2010, Limits of Voltage Fluctuations and Flicker |
Immunity |
CISPR 24:2010/EN 55024:2010 |
EN61000-4-2: 2009 Electrostatic Discharge |
EN61000-4-3: 2006/A2:2010: RF Electromagnetic Field Modulated |
EN61000-4-4: 2004 Fast Transients |
EN61000-4-5: 2006 Surge |
EN61000-4-6: 2009 RF Continuous Conducted |
EN61000-4-8: Power-Frequency Magnetic Field |
EN61000-4-11: Voltage Dips and Voltage Interruptions |
|
Safety |
IEC 62368-1 and EN 62368-1:2014 |
IEC 60950-1 (ed 2); am1 am2 and EN 60950-1: 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013 |
CAN/CSA-C22.2 No. 62368-1-14 and UL 62368-1 |
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1, Second Edition |