• Ethernet Interface |
Number of Ports |
1 |
Speed |
10/100 Mbps, auto MDI/MDIX |
Connector |
8-pin RJ45 |
Magnetic Isolation Protection |
1.5 kV built-in |
• Serial Interface |
Number of Ports |
4 |
Serial Standards |
NPort 5450/5450I/5450-T/5450I-T: RS-232/422/485 (software selectable) |
Connector |
NPort 5410/5450/5450I/5450-T/5450I-T: DB9 male |
Serial Line Protection |
2 kV isolation protection (NPort 5430I/5450I/5450I-T) |
RS-485 Data Direction Control |
ADDC® (Automatic Data Direction Control) |
Pull High/Low Resistor for RS-485 |
1 kΩ, 150 kΩ |
Terminator for RS-485 |
120 Ω |
• Serial Communication Parameters |
Data Bits |
5, 6, 7, 8 |
Stop Bits |
1, 1.5, 2 |
Parity |
None, Even, Odd, Space, Mark |
Flow Control |
RTS/CTS and DTR/DSR (RS-232 only), XON/XOFF |
Baudrate |
50 bps to 921.6 kbps |
• Serial Signals |
RS-232 |
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
RS-422 |
Tx+, Tx-, Rx+, Rx-, GND |
RS-485-4w |
Tx+, Tx-, Rx+, Rx-, GND |
RS-485-2w |
Data+, Data-, GND |
• Software |
Network Protocols |
ICMP, IPv4, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1, HTTP, SMTP, SNTP, Rtelnet, ARP |
Configuration Options |
Web Console, Telnet Console, Windows Utility |
Windows Real COM Drivers |
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded |
Fixed TTY Drivers |
SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X |
Linux Real TTY Drivers |
Linux 2.4.x, 2.6.x, 3.x |
• Mini Screen with Push Buttons (for standard temp. models) |
LCD Panel |
Liquid Crystal Display on the case |
Push Buttons |
Four push buttons for convenient on-site configuration |
• Physical Characteristics |
Housing |
Metal |
Weight |
740 g (1.63 lb) |
Dimensions |
Without mounting kit: 158 x 103 x 33 mm (6.22 x 4.06 x 1.30 in) With mounting kit: 181 x 103 x 33 mm (7.14 x 4.06 x 1.30 in) |
• Environmental Limits |
Operating Temperature |
Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature |
-40 to 75°C (-40 to 167°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Power Requirements |
Input Voltage |
12 to 48 VDC |
Input Current |
NPort 5450/5450-T: 350 mA @ 12 VDC NPort 5450I/5450I-T: 554 mA @ 12 VDC |
• Standards and Certifications |
Safety |
UL 60950-1 |
EMC |
EN 55032/24 |
EMI |
CISPR 32, FCC Part 15B Class A |
EMS |
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF IEC 61000-4-11 DIPs |
Marine |
DNV (standard temp. models only) |
Medical |
EN 60601-1-2 Class B, EN 55011 (NPort 5410/5450/5450I only) |
• Reliability |
Alert Tools |
Built-in buzzer and RTC (real-time clock) |
Automatic Reboot Trigger |
Built-in WDT (watchdog timer) |
• MTBF (mean time between failures) |
Time |
NPort 5450/5450I: 206,903 hrs |
Standard |
Telcordia (Bellcore) Standard TR/SR |