Media Converter Module Indicators |
Power / TST |
This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink when in Loopback test mode. |
Fiber link on / Receive activity (LKF) |
This green LED is operational only when power is applied. The LED is on when the 100Base-FX link is on and flashes with a 50% duty cycle when data is received. |
Copper link on / Receive activity (LKC) |
This green LED is operational only when power is applied. The LED is on when the 100Base-TX link is on and flashes with a 50% duty cycle when data is received. |
Management Module Indicators / reset |
Power |
Blinking green during startup cycle Steady green: module has power and is ready
Red : error
|
ALM |
Red alarm indicator activated when an alert event occurs |
LKC |
Green indicator indicating an active Ethernet link. Blinking indicates RX and TX of data |
100/1000 |
Green - 1000 Mbps link
Yellow - 100 Mbps link
Off - 10 Mbps or no Link
|
Reset button |
Recessed pinhole button resets module |
Connectors |
100Base-TX |
RJ45 connector, 2 pair CAT 5, EIA/TIA 568A/B or better cable
Magnetic Isolation - 1.5kv
|
Fiber Optic Cable |
Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron
Single Mode: 9/125 micron (ITU-T 625)
|
Management ethernet port |
10/100/1000Base-T - RJ45
Auto- MDI/MDIX
|
Management console port |
RS232 Serial RJ45 - Cisco pinout for use with standard CAT5 "rolled cable" (crossover) 9600 to 115k bps 7/8 bits Odd,even, no parity 1/2 stop bits Hardware/software flow control DCD/DSR monitoring |
Packet Transmission Characteristics |
Bit Error Rate (BER) |
|
Switches: On-Board (If Auto/Switch strap is set to Switch) |
Auto-Negotiation (802.3u) |
Enabled (Default) - The media converter uses 802.3u Auto-negotiation on the 100Base-TX interface. It is set to advertise full duplex.
Disabled - The media converter sets the 100Base-TX port to full duplex.
|
Pause |
Pause should be enabled when all devices connected to the media converter support pause. Auto-Negotiation must be Enabled to use this feature.
Enabled (Default) - The Media converter will advertise Pause capability during Auto-Negotiation on the 100Base-TX interface.
Disabled - The Media converter will advertise that it does not have Pause capability during Auto-Negotiation on the 100Base-TX interface.
|
Link Pass Through |
Enabled (Default) - When the state of the receiver is changed on the 100Base-TX interface it is reflected on the 100Base-FX fiber transmitter. When the state of the receiver on the 100Base-FX interface is changed it is reflected on the 100Base-TX transmitter.
When a Far-End Fault Indication is received on the fiber interface the 100Base-TX transmitter is turned off. When the Far-End Fault Indication is cleared the transmitter is turned back on.
Disabled - The 100Base-TX and the 100Base-FX fiber interface operate independently. Far-End Fault indication on the 100Base-FX fiber interface has no effect on the 100Base-TX interface.
|
Far-End Fault (FEF) |
Enabled (Default) - The media converter transmits the Far-End Fault Indication over the 100Base-FX fiber connection whenever a receive failure is detected on the 100Base-FX fiber connection. The media converter continuously monitors the100Base-X fiber connection and clears the Far-End Fault Indication condition when a valid signal is received.
Disabled - Far-End Fault Indications are not transmitted regardless of the condition of the receive signal on the 100Base-FX fiber connection.
|
Remote Loopback |
The media converter can perform a loopback on the 100Base-X fiber interface.
Disabled (Default - Up)
Enabled - The 100Base-X receiver is looped to the 100Base-X transmitter. The 100Base-TX transmitter is taken off the interface.
|
Auto-MDIX (Strap) |
If Auto-Negotiation (802.3u) is enabled, the media converter uses the HP Auto-MDIX method for the 100Base-TX interface. If Auto-Negotiation (802.3u) is disabled the Media converter will use the RX Energy method on the 100Base-TX interface to set the port MDI or MDIX whichever is appropriate.
Enabled (Default) - Either a straight-through or crossover type cable can be used to connect the media converter to the device on the other end of the cable.
Disabled - If the partner device on the other end of the cable does not have the Auto-MDIX feature a specific cable, either a straight-through or crossover will be required to ensure that the media convertor's transmitter and the partner devices transmitter are connected to the others receiver. The Media Convertor's 100Base-TX port is configured as MDI with this switch setting.
|
Configuration Mode (Strap) |
Auto (default) enable management module to overwrite hardware switch settings Switch - Use onboard DIP switches |
Power |
Input Supply Voltage |
( 12 vDC Nominal ) |
Current |
0.33amps at12vdc |
Power Consumption |
3.98watts |
Power Connector |
5.5mm x 9.5mm x 2.1mm barrel socket |
Power Adapter |
Universal AC/DC Adapter |
100-240v AC, regulated DC adapter included |
Environmental Specifications |
Operating Temperature |
0 C to 50 C (32 F to 122 F) |
Storage Temperature |
minimum range of -25 C to 70 C (-13 F to 158 F) |
Operating Humidity |
5% to 90% non-condensing |
Storage Humidity |
5% to 95% non-condensing |
Operating Altitude |
Up to 3,048 meters (10,000 feet) |
Heat Output ( BTU/HR ) |
13.6 |
MTBF (Hours)** |
245,769 without power adaptor 168,532 with power adaptor: |
Chassis |
Metal with an IP20 ingress protection rating |
Mounting |
Din Rail Kit |
Optional |
Rack Mount Kit |
Optional |
Product Weight and Dimensions |
Weight |
0.722 kg |
Dimensions |
175 x 145 x 23 mm |
Packaging |
Shipping Weight |
1.2 kg |
Shipping Dimensions |
300 x 200 x 70 mm |
Regulatory Approvals |
Emissions |
FCC Part 15 Class B*, EN55022 Class B* |
CISPR 22 Class B* CISPR 32:2015/EN 55032:2015 (Class A) CISPR 24:2010/EN 55024:2010 |
EN61000-3-2 |
Immunity |
EN55024 |
Electrical Safety |
UL 60950-1 |
IEC 60950-1(ed 2); am1, am2 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 |
CE |
Laser Safety |
EN 60825-1:2007 |
Fiber optic transmitters on this device meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11. |
Environmental |
Reach, RoHS and WEEE Compliant |
Other |
ECCN: 5A991 |
HTSUS Number: 8517.62.0050 |
CCATS: G134373 |
Perle Limited Lifetime Warranty |