Ambient conditions |
Ambient temperature (operation) |
-20 °C ... 60 °C |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
Permissible humidity (operation) |
30 % ... 95 % (non-condensing) |
Altitude |
5000 m (For restrictions see manufacturer's declaration) |
Degree of protection |
IP20 |
Noise immunity |
EN 61000-6-2:2005 |
Standards and Regulations |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
Type of test |
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
Test result |
5g, 10-150 Hz, 2.5 h, in XYZ direction |
Type of test |
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
Test result |
15g, 11 ms period, half-sine shock pulse |
Shock |
15g in all directions in acc. with IEC 60068-2-27 |
Noise emission |
EN 55011 |
Noise immunity |
EN 61000-6-2:2005 |
Free from substances that could impair the application of coating |
according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
Connection in acc. with standard |
CUL |
Standards/regulations |
EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 |
Vibration (operation) |
In acc. with IEC 60068-2-6: 5g, 150 Hz |
Conformance |
CE-compliant |
ATEX |
II 3 G Ex nA nC IIC T4 Gc X II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) |
UL, USA/Canada |
Class I, Zone 2, AEx nc IIC T5 Class I, zone 2, Ex nC nL IIC T5 X Class I, Div. 2, Groups A, B, C, D |
Optical interface FO |
Number of FO ports |
2 |
Transmit capacity, minimum |
-4 dBm (200/230 µm) -17.6 dBm (50/125 µm) -14 dBm (62,5/125 µm) |
Minimum receiver sensitivity |
-32.5 dBm (50/125 µm) -32.5 dBm (62,5/125 µm) -32.1 dBm (200/230 µm) |
Overrange receiver |
-3 dBm (200/230 µm) |
Wavelength |
850 nm |
Transmission length incl. 3 dB system reserve |
2800 m (with F-K 200/230 8 dB/km with quick mounting connector) 4200 m (with F-G 50/125 2.5 dB/km) 3300 m (with F-G 62,5/125 3.0 dB/km) |
Transmission medium |
PCF fiber Multi-mode fiberglass |
Transmission protocol |
Protocol-transparent to the RS-485 interface |
Connection method |
B-FOC (duplex ST®) |
General |
Bit delay |
≤ 1 bit |
Bit distortion, input |
± 35 % (permitted) |
Bit distortion, output |
< 6.25 % |
Electrical isolation |
VCC // RS-485 |
Test voltage data interface/power supply |
1.5 kVrms (50 Hz, 1 min.) |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
Noise emission |
EN 55011 |
Net weight |
210.08 g |
Housing material |
PA 6.6-FR |
Color |
green |
MTBF |
159 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) 24 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
Conformance |
CE-compliant |
ATEX |
II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) |
UL, USA/Canada |
Class I, Zone 2, AEx nc IIC T5 Class I, zone 2, Ex nC nL IIC T5 X Class I, Div. 2, Groups A, B, C, D |
Digital outputs |
Output name |
Relay output |
Output description |
Alarm output |
Number of outputs |
1 |
Maximum switching voltage |
60 V DC 42 V AC |
Limiting continuous current |
0.46 A |
Power supply |
Nominal supply voltage |
24 V DC (With UL approval) |
Supply voltage range |
18 V DC ... 30 V DC |
Max. current consumption |
130 mA |
Typical current consumption |
120 mA (24 V DC) |
Connection method |
COMBICON plug-in screw terminal block |
Serial interface |
Interface 1 |
RS-485 interface, 2-wire |
Operating mode |
Semi-duplex |
Connection method |
Pluggable screw connection |
File format/coding |
UART (11/10 bit switchable; NRZ), slip-tolerant |
Data direction switching |
Automatic control |
Transmission medium |
Copper |
Transmission length |
≤ 1200 m (depending on the data rate, with shielded, twisted data cable) |
Termination resistor |
390 Ω 220 Ω 390 Ω (Can be connected) |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
14 |
Serial transmission speed |
4.8/ 9.6/ 19.2/ 38.4/ 57.6/ 75/ 93.75/ 115.2/ 136/ 187.5/ 375/ 500 kbps |
Dimensions |
Width |
35 mm |
Height |
99 mm |
Depth |
105 mm |
|
Environmental Product Compliance |
China RoHS |
Environmentally Friendly Use Period = 50 |
Reach and RoHS Compliant |
Reach and RoHS Compliant |
Approvals |
|
cUL Listed cULus Listed UL Listed ATEX EAC DNV cUL Recognized cULus Recognized UL Recognized |