• Technology |
Standards |
IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseX IEEE 802.3x for Flow Control IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid STP IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP |
Protocols |
IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, LLDP, EtherNet/IP, Modbus/TCP, IEEE 1588 PTP V2, IPv6, NTP Server/Client |
MIB |
MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9 |
Flow Control |
IEEE 802.3x flow control, back pressure flow control |
• Switch Properties |
Priority Queues |
4 |
Max. Number of Available VLANs |
64 |
VLAN ID Range |
VID 1 to 4094 |
IGMP Groups |
256 |
MAC Table Size |
8 K |
Packet Buffer Size |
1 Mbit |
• Interface |
Fast Ethernet |
2 or 4 slots for any combination of 4-port interface modules, 10/100BaseT(X) or 100BaseFX |
Gigabit Ethernet |
3 10/100/1000BaseT(X) with 100/1000BaseSFP combo slots (EDS-611 and EDS-619 only) |
Console Port |
RS-232 (RJ45 connector) |
DIP Switches |
Turbo Ring, Master, Coupler, Reserve |
System LED Indicators |
PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL, G1/G2/G3 (EDS-611 and EDS-619 only) |
Alarm Contact |
1 relay output with current carrying capacity of 1 A @ 24 VDC |
Digital Inputs |
1 input with the same ground, but electrically isolated from the electronics. • +13 to +30V for state “1” • -30 to +3V for state “0” • Max. input current: 8 mA |
• Power Requirements |
Input Voltage |
12/24/48 VDC, redundant dual inputs |
Input Current |
EDS-608: 0.16A @ 24 V EDS-611: 0.31A @ 24 V EDS-616: 0.25A @ 24 V EDS-619: 0.31A @ 24 V |
Overload Current Protection |
Present |
Connection |
1 removable 5-contact and 1 removable 6-contact terminal block |
Reverse Polarity Protection |
Present |
• Physical Characteristics |
Housing |
IP30 protection |
Dimensions |
EDS-608/611 Series: 124.9 x 151 x 157.2 mm (4.92 x 5.95 x 6.19 in) EDS-616/619 Series: 185 x 151 x 157.2 mm (7.28 x 5.95 x 6.19 in) |
Weight |
EDS-608: 2080 g EDS-611: 2260 g EDS-616: 2780 g EDS-619: 2950 g |
Installation |
DIN-Rail mounting, wall mounting (with optional kit) |
• Environmental Limits |
Operating Temperature |
Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Standards and Certifications |
Safety |
UL 508, UL 60950-1, EN 60950-1 |
Hazardous Location |
UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nCnAnL IIC T4 |
EMI |
FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 61000-6-4 |
EMS |
EN 61000-6-2 EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3, EN 61000-4-6 (CS) Level 3, EN 61000-4-8, EN 61000-4-29 |
Marine |
DNV, GL, LR, ABS, NK |
Traffic Control |
NEMA TS2 |
Rail Traffic |
EN 50121-4 |
Shock |
IEC 60068-2-27 |
Freefall |
IEC 60068-2-32 |
Vibration |
IEC 60068-2-6 |
Note |
Please check Moxa’s website for the most up-to-date certification status. |
• MTBF (mean time between failures) |
Time |
EDS-608: 506,219 hrs EDS-611: 483,344 hrs EDS-616: 546,937 hrs EDS-619: 475,816 hrs |
Database |