Environmental Product Compliance |
China RoHS |
Environmentally Friendly Use Period = 25; |
General |
Net weight |
2 kg |
Efficiency |
> 91 % (With 600 V DC and nominal values) |
Insulation voltage input/output |
4 kV AC (type test) |
|
2 kV AC (routine test) |
Insulation voltage input / PE |
2 kV AC (type test) |
|
2 kV AC (routine test) |
Insulation voltage output / PE |
500 V DC (routine test) |
Protection class |
I (with PE connection) |
Degree of protection |
IP20 |
MTBF (IEC 61709, SN 29500) |
|
|
> 701000 h (40 °C) |
Mounting position |
horizontal DIN rail NS 35, EN 60715 |
Assembly instructions |
alignable: horizontally 0 mm, vertically 50 mm |
Standards and Regulations |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
Noise immunity |
EN 61000-6-2:2005 |
Connection in acc. with standard |
CUL |
Standards/regulations |
EN 61000-4-2 |
Contact discharge |
4 kV (Test Level 2) |
Standards/regulations |
EN 61000-4-3 |
Frequency range |
80 MHz ... 3 GHz |
Test field strength |
10 V/m |
Frequency range |
1.4 GHz ... 2 GHz |
Test field strength |
3 V/m |
Standards/regulations |
EN 61000-4-4 |
Comments |
Criterion B |
Standards/regulations |
EN 61000-6-3 |
|
EN 61000-4-6 |
Frequency range |
150 kHz ... 80 MHz |
Voltage |
10 V (Test Level 3) |
Standards/regulations |
EN 61000-4-11 |
Low Voltage Directive |
Conformance with LV directive 2006/95/EC |
Standard - Electrical safety |
EN 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage |
EN 60950-1 (SELV) |
|
EN 60204 (PELV) |
Standard - Safe isolation |
DIN VDE 0100-410 |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment |
EN 50178 |
Standard – Limitation of mains harmonic currents |
EN 61000-3-2 |
UL approvals |
UL/C-UL listed UL 508 |
|
UL/C-UL Recognized UL 60950-1 |
Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
|
15 Hz ... 150 Hz, 2.3g, 90 min. |
Rail applications |
EN 50121-4 |
Connection data, input |
Connection method |
Screw connection |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
14 |
Stripping length |
9 mm |
Screw thread |
M2,5 |
Output data |
Nominal output voltage |
24 V DC ±1 % |
Setting range of the output voltage (USet) |
22.5 V DC ... 29.5 V DC (UIN > 475 V DC) |
|
22.5 V DC ... 28 V DC (UIN ≤ 475 V DC) |
Nominal output current (IN) |
20 A (-25 °C ... 55 °C) |
Derating |
55 °C ... 70 °C (2.5%/K) |
Connection in parallel |
Yes, for redundancy and increased capacity |
Connection in series |
yes |
Feedback resistance |
35 V DC |
Protection against surge voltage on the output |
Yes, < 35 V DC |
Max. capacitive load |
Unlimited |
Active current limitation |
Approx. 25 A (for short-circuit) |
Control deviation |
< 1 % (change in load, static 10 % ... 90 %) |
|
< 2 % (change in load, dynamic 10 % ... 90 %) |
|
< 0.1 % (change in input voltage ±10 %) |
Residual ripple |
< 40 mVPP |
Output power |
480 W |
Typical response time |
< 1 s |
Peak switching voltages nominal load |
< 10 mVPP |
Maximum power dissipation in no-load condition |
3.8 W |
Power loss nominal load max. |
45 W |
Dimensions |
Width |
115 mm |
Height |
130 mm |
Depth |
152.5 mm |
Weight per piece |
1780.0 GRM |
Input data |
Nominal input voltage range |
600 V DC |
Input voltage range |
450 V DC ... 840 V DC (Dielectric strength up to 900 V DC) |
Frequency range DC |
0 Hz |
Discharge current to PE |
< 3.5 mA |
Current consumption |
0.9 A (600 V DC) |
Nominal power consumption |
527.3 VA |
Inrush surge current |
< 26 A |
Mains buffering |
typ. 15 ms (600 V DC) |
Choice of suitable circuit breakers |
4 A ... 6 A (1000 V DC) |
Power factor (cos phi) |
1 |
Type of protection |
Transient surge protection |
Protective circuit/component |
Varistor |
|
Ambient conditions |
Degree of protection |
IP20 |
Ambient temperature (operation) |
-25 °C ... 70 °C (> 55° C derating : 2.5%/K) |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
Climatic class |
3K3 (in acc. with EN 60721) |