Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP+) |
2 |
|
Full/Half duplex mode |
|
Auto MDI/MDI-X connection |
|
Auto negotiation speed |
PoE Ports (10/100BaseT(X), RJ45 connector) |
8 |
|
Full/Half duplex mode |
|
Auto MDI/MDI-X connection |
|
Auto negotiation speed |
Standards |
IEEE 802.1D-2004 for Spanning Tree Protocol |
|
IEEE 802.1p for Class of Service |
|
IEEE 802.1Q for VLAN Tagging |
|
IEEE 802.1s for Multiple Spanning Tree Protocol |
|
IEEE 802.1w for Rapid Spanning Tree Protocol |
|
IEEE 802.1X for authentication |
|
IEEE 802.3 for 10BaseT |
|
IEEE 802.3ab for 1000BaseT(X) |
|
IEEE 802.3ad for Port Trunk with LACP |
|
IEEE 802.3af/at for PoE/PoE+ output |
|
IEEE 802.3u for 100BaseT(X) and 100BaseFX |
|
IEEE 802.3x for flow control |
|
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX |
Ethernet Software Features |
|
Filter |
GMRP, GVRP, IGMP v1/v2, Port-based VLAN |
Industrial Protocols |
EtherNet/IP, Modbus TCP |
Management |
Back Pressure Flow Control, BOOTP, DDM, DHCP Option 66/67/82, DHCP Server/Client, Fiber check, Flow control, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTP |
MIB |
LACP, Link Aggregation, MSTP, RSTP, STP, Turbo Chain, Turbo Ring v1/v2 |
Redundancy Protocols |
|
Security |
HTTPS/SSL, Port Lock, RADIUS, TACACS+, SSH |
Time Management |
NTP Server/Client, SNTP |
Switch Properties |
|
IGMP Groups |
1024 |
MAC Table Size |
8K |
Max. No. of VLANs |
64 |
Packet Buffer Size |
1 Mbits |
Priority Queues |
4 |
VLAN ID Range |
VID 1 to 4094 |
Serial Interface |
|
Console Port |
RS-232 (TxD, RxD, GND), 10-pin RJ45 (19200, n, 8, 1) |
DIP Switch Configuration |
|
Ethernet Interface |
Turbo Ring, Master, Coupler, Reserve |
Input/Output Interface |
|
Alarm Contact Channels |
1, Relay output with current carrying capacity of 0.5 A @ 48 VDC |
Digital Input Channels |
1 |
Digital Inputs |
Max. input current: 8 mA |
|
+13 to +30 V for state 1 |
|
-30 to +3 V for state 0 |
Power Parameters |
|
Input Voltage |
48 VDC, Redundant dual inputs |
Operating Voltage |
44 to 57 VDC |
Input Current |
5.36 A @ 48 VDC |
Power Consumption (Max.) |
Max. 17.28 W full loading without PDs’ consumption |
Power Budget |
Max. 240 W for total PD consumption |
|
Max. 36 W for each PoE port |
Connection |
2 removable 2-contact terminal block(s) |
Overload Current Protection |
Supported |
Reverse Polarity Protection |
Supported |
Physical Characteristics |
|
Housing |
Metal |
IP Rating |
IP30 |
Dimensions |
79.2 x 135 x 105 mm (3.12 x 5.31 x 4.13 in) |
Weight |
1030 g (2.28 lb) |
Installation |
DIN-rail mounting, Wall mounting (with optional kit) |
Environmental Limits |
|
Operating Temperature |
EDS-P510A-8PoE-2GTXSFP: -10 to 60°C (14 to 140°F) |
|
EDS-P510A-8PoE-2GTXSFP-T: -40 to 75°C (-40 to 167°F) |
Storage Temperature (package included) |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
Standards and Certifications |
|
Safety |
UL 508 |
EMC |
|
EMI |
EN 55032/24 |
|
CISPR 32, FCC Part 15B Class A |
EMS |
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV |
|
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m |
|
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV |
|
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV |
|
IEC 61000-4-6 CS: 10 V |
|
IEC 61000-4-8 PFMF |
Hazardous Locations |
Class I Division 2 |
Railway |
EN 50121-4 |
Traffic Control |
NEMA TS2 |
Freefall |
IEC 60068-2-31 |
Shock |
IEC 60068-2-27 |
Vibration |
IEC 60068-2-6 |
MTBF |
|
Time |
708,972 hrs |