Alarm Contact Channels |
2, Relay output with current carrying capacity of 1 A @ 24 VDC |
Digital Input Channels |
2 |
Digital Inputs |
+13 to +30 V for state 1 |
|
-30 to +3 V for state 0 |
|
Max. input current: 8 mA |
10/100/1000BaseT(X) Ports (RJ45 connector) |
4 |
|
Auto negotiation speed |
|
Full/Half duplex mode |
|
Auto MDI/MDI-X connection |
Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP+) |
5 |
Standards |
|
|
IEEE 802.1D-2004 for Spanning Tree Protocol |
|
IEEE 802.1p for Class of Service |
|
IEEE 802.1Q for VLAN Tagging |
|
IEEE 802.1s for Multiple Spanning Tree Protocol |
|
IEEE 802.1w for Rapid Spanning Tree Protocol |
|
IEEE 802.1X for authentication |
|
IEEE 802.3 for 10BaseT |
|
IEEE 802.3ab for 1000BaseT(X) |
|
IEEE 802.3ad for Port Trunk with LACP |
|
IEEE 802.3u for 100BaseT(X) |
|
IEEE 802.3x for flow control |
|
IEEE 802.3z for 1000BaseX |
Filter |
802.1Q VLAN, GMRP, GVRP, IGMP v1/v2, Port-based VLAN |
Industrial Protocols |
EtherNet/IP, Modbus TCP |
Management |
Back Pressure Flow Control, BOOTP, DDM, DHCP Option 66/67/82, DHCP Server/Client, Flow control, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTP |
MIB |
Bridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RMON MIB Groups 1, 2, 3, 9, RSTP MIB |
Redundancy Protocols |
Link Aggregation, MSTP, RSTP, STP, Turbo Chain, Turbo Ring v1/v2 |
|
|
Security |
Broadcast storm protection, HTTPS/SSL, Port Lock, RADIUS, SSH, TACACS+, SNMPv3 |
Time Management |
NTP Server/Client, SNTP |
|
|
IGMP Groups |
256 |
MAC Table Size |
8K |
Max. No. of VLANs |
64 |
Packet Buffer Size |
1 Mbits |
Priority Queues |
4 |
VLAN ID Range |
VID 1 to 4094 |
LED Interface |
|
LED Indicators |
PWR1, PWR2, FAULT, 10/100/1000M(TP port), 100/1000M (SFP port), MSTR/HEAD, CPLR/TAIL |
Serial Interface |
|
Console Port |
RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1) |
|
|
DIP Switch Configuration |
|
DIP Switches |
Turbo Ring, Master, Coupler, Reserve |
Power Parameters |
|
Power Connector |
2 removable 6-contact terminal block(s) |
|
|
Input Current |
0.69 A @ 24 VDC |
|
|
Input Voltage |
12/24/48 VDC, Redundant dual inputs |
Operating Voltage |
9.6 to 60 VDC |
Overload Current Protection |
Supported |
Reverse Polarity Protection |
Supported |
Physical Characteristics |
|
Housing |
Metal |
IP Rating |
IP30 |
Dimensions |
87.1 x 135 x 107 mm (3.43 x 5.31 x 4.21 in) |
Weight |
1510 g (3.33 lb) |
Installation |
DIN-rail mounting, Wall mounting (with optional kit) |
Environmental Limits |
|
Operating Temperature |
EDS-G509: 0 to 60°C (32 to 140°F) |
|
EDS-G509-T: -40 to 75°C (-40 to 167°F) |
Storage Temperature (package included) |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
Standards and Certifications |
|
Freefall |
IEC 60068-2-32 |
EMC |
EN 55032/24 |
EMI |
CISPR 32, FCC Part 15B Class A |
EMS |
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV |
|
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m |
Maritime |
ABS, DNV-GL, LR, NK |
Railway |
EN 50121-4 |
Safety |
EN 60950-1, UL 508 |
Shock |
IEC 60068-2-27 |
Vibration |
IEC 60068-2-6 |
MTBF |
|
Time |
598,659 hrs |
Standards |
Telcordia (Bellcore), GB |
|
|
|