SCS8C |
SCS8C DAC |
SCS16C & SCS16C-DSFP |
SCS16C DAC & SCS16C-DSFP DAC |
SCS32C |
SCS32C DAC |
SCS48C |
SCS48C DAC |
Processor |
MPC8349E, 400 Mhz, 750 MIPS |
Memory |
RAM MB |
64 |
64 |
64 |
64 |
128 |
128 |
128 |
128 |
Flash MB |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
Interface Ports |
Number of Serial Ports |
8 |
8 |
16 |
16 |
32 |
32 |
48 |
48 |
Serial Port Interface |
RS232 DTE on RJ45 |
Sun / Solaris |
Sun / Oracle ‘Solaris' Safe - no "break signal" sent during power cycle causing costly server re-boots or downtime |
Serial Port Speeds |
50bps to 230Kbps with customizable baud rate support |
Data Bits |
5,6,7,8, 9-bit protocol support |
Parity |
Odd, Even, Mark, Space, None |
Flow Control |
Hardware, Software, Both, None |
Serial Port Protection |
15Kv Electrostatic Discharge Protection ( ESD ) |
Local Console Port |
RS232 on RJ45 with DB9 adapter ( provided ) |
Network |
Dual 10/100/1000-base TX Ethernet RJ45 (on all models except SCS16C-DSFP) SCS16C-DSFP: Dual SFP Slots for Copper or Fiber Network Connection |
Software selectable Ethernet speed 10/100/1000, Auto |
Software selectable Half/Full/Auto duplex |
Ethernet Isolation |
1.5Kv Magnetic Isolation |
Integrated Modem |
Optional V.92 modem card available with RJ11 jack |
Integrated Wireless |
Optional PC Adapter Card for integration of 3rd party wireless PCMCIA cellular cards (GSM/GPRS/3G) |
Fiber Support |
Dual SFP slots are available on the SCS16C-DSFP model. For all other models, Perle supports 3rd party Gigabit Fiber Cards via the standard PCI Interface Slot. Alternatively, connect a Perle Standalone Media Converter to the IOLAN SCS Ethernet port for Fiber to Ethernet conversion. |
Power |
SCS8C |
SCS8C DAC |
SCS16C & SCS16C-DSFP |
SCS16C DAC & SCS16C-DSFP DAC |
SCS32C |
SCS32C DAC |
SCS48C |
SCS48C DAC |
Redundant Power |
|
Dual power supply |
|
Dual power supply |
|
Dual power supply |
|
Dual power supply |
|
|
Nominal Input Voltage |
110/230v AC |
Input Voltage Range |
100-240v AC |
AC Input Frequency |
47-63Hz |
Current Consumption @ 100v ( Amps ) |
0.17 |
0.20 |
0.18 |
0.21 |
0.19 |
0.22 |
0.2 |
0.23 |
Current Consumption @ 240v ( Amps ) |
0.07 |
0.08 |
0.08 |
0.09 |
0.08 |
0.09 |
0.08 |
0.09 |
Typical Power Consumption ( Watts ) |
17 |
19.5 |
18 |
20.5 |
19 |
21.5 |
20 |
22.5 |
Power Line Protection |
Fast transients: 1 KV (EN61000-4-4 Criteria B) |
Surge: 2KV (EN61000-4-5 common mode), 1KV (EN61000-4-5 differential and common modes) |
Indicators |
LEDs |
Power |
System Ready |
Network Link activity |
Serial: Transmit and Receive data per port |
Environmental Specifications |
Heat Output ( BTU/HR ) |
58 |
67 |
62 |
70 |
65 |
74 |
69 |
77 |
MTBF ( Hours )* |
130539 |
99587 |
122926 |
95094 |
111053 |
87829 |
115980 |
90884 |
Operating Temperature |
0C to 55C, 32F to 131F |
Storage Temperature |
-40C to 85C, -40F to 185F |
Humidity |
5 to 95% (non condensing) for both storage and operation. |
Case |
SECC Zinc plated sheet metal (1 mm) |
Ingress Protection Rating |
IP30 |
Mounting |
1U - 19" rack, front and rear mounting hardware included |
Product Weight and Dimensions |
Weight |
3.0 kg |
3.2 kg |
3.1 kg |
3.4 kg |
3.2 kg |
3.5 kg |
3.5 kg |
3.6 kg |
Dimensions |
1U Rack form factor - 26.4 x 43.4 x 4.4 (cm), 10.38 x 17.1 x 1.75 (in) |
Packaging |
Shipping Dimensions |
59 x 36 x 9cm |
Shipping Weight |
4.0 kg |
4.2 kg |
4.2 kg |
4.4 kg |
4.4 kg |
4.8 kg |
4.5 kg |
4.9 kg |
Regulatory Approvals |
Emissions |
FCC Part 15, Subpart B, Class A |
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A |
ICES-003, Issue 4, February 2004 (Canada) |
CISPR 32:2015/EN 55032:2015 (Class A) |
EN61000-3-2 : 2010, Limits for Harmonic Current Emissions |
EN61000-3-3 : 2010, Limits of Voltage Fluctuations and Flicker |
Immunity |
CISPR 24:2010/EN 55024:2010 |
EN61000-4-2: Electrostatic Discharge |
EN61000-4-3: RF Electromagnetic Field Modulated |
EN61000-4-4: Fast Transients |
EN61000-4-5: Surge |
EN61000-4-6: RF Continuous Conducted |
EN61000-4-8: Power-Frequency Magnetic Field |
EN61000-4-11: Voltage Dips and Voltage Interruptions |
Safety |
IEC 60950-1(ed 2); am1, am2 and EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 |
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1, First Edition April 1st 2003 (Recognized Component) |
Other |
Reach, RoHS and WEEE Compliant Directive 2011/65/EU restriction of the use of certain hazardous substances in electrical and electronic equipment and meets the following standard:: EN 50581:2012 |
CCATS - G168387 |
ECCN - 5A992 |
HTSUS Number: 8471.80.1000 |
Perle Limited Lifetime warranty |