Serial interface |
Interface 1 |
V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1 |
Interface |
RS-232 |
Connection method |
D-SUB 9 plug |
Transmission length |
max. 15 m |
Termination resistor |
390 Ω - 180 Ω - 390 Ω (can be connected) |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
13 |
Data flow control/protocols |
Software handshake, Xon/Xoff, hardware handshake (RTS/CTS), 3964R-compatible, Modbus (RTU/ASCII), transparent protocol - additional protocols supported |
Serial transmission speed |
0.11/0.3/1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2/230.4 kbps, NRZ |
Interface 2 |
SHDSL interface according to ITU-T G.991.2.bis |
Connection method |
2 x 2-pos. COMBICON plug-in screw terminal blocks |
Transmission length |
up to 20 km (Depending on data rate and cable cross section) |
Serial transmission speed |
4-wire operation: 64 kbps ... 30 Mbps |
|
2-wire operation: 32 kbps ... 15.3 Mbps |
Interface 3 |
USB 2.0 |
Connection method |
Mini-USB type B, 5-pos. |
Transmission length |
< 5 m (only for configuration and diagnostics) |
Interface 4 |
RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1 |
Interface |
RS-422 |
Connection method |
Plug-in/screw connection via COMBICON |
File format/coding |
Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length |
Transmission length |
≤ 1200 m |
Termination resistor |
390 Ω - 180 Ω - 390 Ω (can be connected) |
Data flow control/protocols |
Automatic control // Modbus RTU/ASCII |
Serial transmission speed |
1.2/2.4/4.8/7.0/9.6/19.2/38.4/57.6/75/93.75/115.2/136/187.5/375/500/1500/2000 kbps, NRZ |
Interface 5 |
RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire |
Interface |
RS-485 |
Connection method |
Plug-in/screw connection via COMBICON |
File format/coding |
Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length |
Transmission length |
up to 1200 m |
Termination resistor |
390 Ω - 180 Ω - 390 Ω (can be connected) |
Protocols supported |
Transparent, including 3964R protocol |
Data flow control/protocols |
Automatic control // Modbus RTU/ASCII |
Serial transmission speed |
1.2/2.4/4.8/7.0/9.6/19.2/38.4/57.6/75/93.75/115.2/136/187.5/375/500/1500/2000 kbps, NRZ |
Digital outputs |
Output name |
Digital output |
Number of outputs |
2 |
Voltage output signal |
depending on the operating voltage |
Current output signal |
≤ 150 mA (Short-circuit-proof) |
Behavior of the outputs |
Deactivated for device supply via DIN rail connector |
Function |
Management |
User-friendly software: Guided configuration, plausibility checks, diagnostic functions, log book |
Status and diagnostic indicators |
LEDs: VCC (supply voltage), RD/TD (serial data traffic), ERR (errors), TERM (termination resistor active), RS-232 (RS-232 active) |
2 x LINK / 2 x STAT (DSL data traffic port A and port B), DIAG (diagnostic messages) |
Ambient Conditions |
Ambient temperature (operation) |
-20 °C ... 60 °C (for derating, see technical documentation) |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
Permissible humidity (operation) |
10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) |
10 % ... 95 % (non-condensing) |
Altitude |
5000 m (For restrictions see manufacturer's declaration) |
Degree of protection |
IP20 |
Noise immunity |
EN 61000-6-2 |
General |
Electrical isolation |
DIN EN 50178 (VCC, RS-232 // RS-422, RS-485 // DSL (A) // DSL (B) // FE) |
Test voltage data interface/power supply |
1.5 kVrms (50 Hz, 1 min.) |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
Net weight |
339.4 g |
Housing material |
PA 6.6-FR |
Color |
green |
MTTF |
693 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day)) |
301 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) |
121 Years (SN 29500 standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day)) |
Conformance |
CE-compliant |
Noise emission |
EN 55011 |
Power supply |
Nominal supply voltage |
24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply) |
5 V DC (configuration only, via mini-USB type B) |
|
Supply voltage range |
18 V DC ... 30 V DC |
|
Typical current consumption |
< 180 mA (24 V DC) |
|
Connection method |
COMBICON plug-in screw terminal block |
|
Dimensions |
|
Width |
35 mm |
|
Height |
99 mm |
|
Depth |
114.5 mm |
|